Bentley WaterGEMS CONNECT Edition Help

Check Valves

For series pipes, if any pipe has a check valve, then the resulting pipe will have a check valve. For parallel pipes, if both pipes have check valves, then the resulting pipe will have a check valve.

The degenerative case is when one of the parallel pipes has a check valve. This should not happen in terms of good engineering. If it does, the parallel pipes should not be combined and a warning message should be issued.